CP was retained as part of a design/build team for the installation of a radiography facility consisting of a neutron imager, electrical controls and cooling cabinets; high voltage power supply; and auxiliary equipment. The scope of the design work included a new process: refrigerated recirculating fluid chiller, air compressor and associated distribution piping, exhaust gas ventilation system; power distribution to all equipment; electrical safeties and interlocks; and new concrete shield walls.